PE, SMP, HDP or PVDF: How to Choose a Paint System for Colour-Coated Steel Roofing

A roof panel is a lighter duty than a whiteboard, not a harder one. The same three things decide whether it still looks right after five summers: adhesion at the fold, zinc at the cut edge, and a topcoat that was actually cured.
Paint either holds or it doesn’t, and you find out at the fold. Writing surfaces taught us where paint fails — at the fold, the cut edge, the lap. Building panels fail in the same three places.
The four paint systems
We supply polyester (PE), silicone-modified polyester (SMP), high-durability polyester (HDP) and PVDF (fluorocarbon). Topcoat dry film thickness is 20–25 µm for PE, SMP and HDP, and 25–35 µm for PVDF. Gloss is 30–50 GU at 60°.
For twenty-six years we have coated writing surfaces at 22–24 µm and 88–95 GU, on a panel a teacher looks at from forty centimetres. A roof panel is a far lighter duty than that. The numbers below are the building-panel specification, not the writing-surface one.
| System | Type | Topcoat DFT | Outdoor life* | Best for |
|---|---|---|---|---|
| PE | Polyester | 20–25 µm | 8–12 years | Industrial roofing, inland, sheds |
| SMP | Silicone-modified | 20–25 µm | 12–15 years | General roofing, better chalk resistance |
| HDP | High-durability | 20–25 µm | 15–20 years | Higher UV, visible facades |
| PVDF | Fluorocarbon | 25–35 µm | 20–25+ years | Coastal, high UV, prestige projects |
* Indicative service life in a moderate climate, topcoat only. Actual life depends on atmosphere, orientation and edge condition. We quote a system, not a guarantee. Tell us the site and we will recommend a system rather than a number.
Zinc, substrate and the six layers
Colour-coated coil is a stack, not a paint. From the steel up:
| # | Layer | Material | Thickness | Job |
|---|---|---|---|---|
| 1 | Steel substrate | DX51D / SGCC / S280GD | 0.30–1.00 mm | Stiffness and forming |
| 2 | Zinc | Z100–Z275 | 137 g/m²/side at Z275 | Sacrificial protection at cut edges |
| 3 | Pretreatment | Chromate-free or Cr³⁺ | under 1 µm | Adhesion |
| 4 | Primer | Epoxy / polyurethane | 5–7 µm | Corrosion barrier, grip for the topcoat |
| 5 | Topcoat | PE / SMP / HDP / PVDF | 20–25 µm, PVDF 25–35 µm | Colour, UV, weather |
| 6 | Back coat | Polyester | 7–12 µm | Underside protection |
Standards are EN 10169, ASTM A755, JIS G3312 or GB/T 12754. Width is 600–1250 mm. For roofing, thickness is typically 0.40–0.80 mm within the 0.30–1.00 mm range. T-bend is 2T–3T, with no cracking or delamination. Pencil hardness is ≥ HB. Salt spray is tested to the hours agreed in your specification.
PPGI is a zinc-coated substrate; PPGL is aluminium-zinc (AZ). GL resists surface corrosion longer in open exposure; GI protects cut edges better. For a coastal roof, GL with PVDF; for inland sheds, PPGI with polyester is the economical answer.
Colour: twelve standards, and the rest of the RAL book
These twelve are the ones that ship most often: RAL 9002 grey white, 9010 pure white, 7016 anthracite, 7035 light grey, 8017 chocolate brown, 3009 oxide red, 3020 traffic red, 5010 gentian blue, 5005 signal blue, 6020 chrome green, 1015 light ivory, and 9006 white aluminium.
Anything else in RAL is a 2-tonne run and about ten extra days. We can also match to a sample. Screen colours are indicative; physical RAL cards and painted A4 samples are sent on request, freight collect. Colour is held to ΔE ≤ 1.5 within a batch.
Coil, flat sheet or profiled
Coil — for your own roll-forming or cut-to-length line. 600–1250 mm, 3–5 t, inner diameter 508 mm.
Flat sheet — 0.30–1.00 mm, levelled and cut to 500–6000 mm, palletised with edge protection.
Profiled — 840 / 900 / 750 / 1050, rolled to your length, 0.30–0.80 mm, maximum length 11.8 m. See the profiled roofing page for the section drawings.
On profiled sheet, 0.40–0.60 mm is the working range. 0.30 mm exists and sells, but a coastal roof in 0.30 mm is a repair waiting to happen; 0.45–0.55 mm covers most industrial work. A 12-metre sheet does not fit in a 20-foot container: the maximum sheet is 5.8 m in a 20GP and 11.8 m in a 40GP or 40HQ. Quote it by square metre, load it by cubic metre — profiled sheet is volume cargo, not weight cargo.
What we inspect on every coil
- Topcoat and primer DFT — magnetic gauge, per coil
- T-bend — 180° fold, no cracking or delamination at the bend
- Cross-hatch adhesion — 0 % loss
- MEK double rubs — 100 passes, no colour transfer
- Gloss — 60° head
- Colour — ΔE ≤ 1.5 within a batch
- Salt spray — tested to the hours agreed in your specification
- MTC to EN 10204 3.1 with every coil
Third-party inspection (SGS / BV / TÜV) at our plant before loading is welcome.
Minimum, mix and lead time
Minimum is 2 t per colour and size. A container can mix colours and thicknesses. Lead time is 10–15 days for stock colours, 20–25 days for a made-to-order colour or thickness. Profiled sheet is 15–20 days, or 20–25 days if the coil itself has to be coated to your colour first.
*— Yueyang Technology, Bazhou, Hebei. Write to us — David Hu, General Manager.*